Ball Mill (Perfect Mixing, Dynamic): Difference between revisions
Scott Munro (talk | contribs) m (1 revision imported) |
imported>Scott.Munro m (→Model theory) |
||
(13 intermediate revisions by 3 users not shown) | |||
Line 7: | Line 7: | ||
== Model theory == | == Model theory == | ||
{{Restricted content}} | |||
<hide> | |||
{{Model theory (Text, Mill, Perfect Mixing, Population Balance, Dynamic)}} | |||
< | |||
=== Time step discretisation === | === Time step discretisation === | ||
{{Model theory (Text, Mill, Perfect Mixing, Dynamic, Time Step)}} | |||
=== Breakage rate === | === Breakage rate === | ||
Line 73: | Line 24: | ||
The steady-state Perfect Mixing model scaling factors for ''mill diameter'', ''load fraction'', ''fraction critical speed'', ''work index'' and ''ball diameter'' are assumed to be explicitly related to the breakage rate and are applied to the <math>R_i</math> function here, i.e.: | The steady-state Perfect Mixing model scaling factors for ''mill diameter'', ''load fraction'', ''fraction critical speed'', ''work index'' and ''ball diameter'' are assumed to be explicitly related to the breakage rate and are applied to the <math>R_i</math> function here, i.e.: | ||
:<math>R_{Sim} = R_{ | :<math>R_{\rm Sim} = R_{\rm Orig} \cdot f_{\rm D} \cdot f_{\rm LF} \cdot f_{\rm CS} \cdot f_{\rm WI} \cdot f_{\rm Db}</math> | ||
{{Model theory (Text, Ball Mill, Perfect Mixing, Breakage Scaling)}} | |||
The [[Ball Mill (Perfect Mixing)#Discharge rate|discharge rate scaling factor]], <math>D^*</math>, is excluded from the breakage rate scaling term and is dealt with separately within the model (see [[Ball Mill (Perfect Mixing, Dynamic)|Slurry filling and discharge]], below). | The [[Ball Mill (Perfect Mixing)#Discharge rate|discharge rate scaling factor]], <math>D^*</math>, is excluded from the breakage rate scaling term and is dealt with separately within the model (see [[Ball Mill (Perfect Mixing, Dynamic)|Slurry filling and discharge]], below). | ||
Line 108: | Line 32: | ||
=== Discharge rate === | === Discharge rate === | ||
{{Model theory (Text, Mill, Perfect Mixing, Dynamic, Discharge Rate)}} | |||
=== Appearance function === | === Appearance function === | ||
{{Model theory (Text, Ball Mill, Perfect Mixing, Appearance)}} | |||
=== Internal mesh series === | === Internal mesh series === | ||
{{Model theory (Text, Ball Mill, Perfect Mixing, Internal mesh)|Perfect Mixing}} | |||
=== Multi-component modelling === | === Multi-component modelling === | ||
{{Model theory (Text, Ball Mill, Perfect Mixing, Multi-component)|Perfect Mixing|breakage rate}} | |||
=== Slurry filling and discharge === | === Slurry filling and discharge === | ||
Line 186: | Line 80: | ||
The quantity of slurry in the mill at the point of trunnion overflow is determined by the mill dimensions and charge geometry. The [[Ball Mill (Overfilling)#Shi|method described by Shi (2016)]] is used to compute the volumetric sum of slurry within the charge void space and slurry pool at the overflow condition.{{Shi_(2016)}} | The quantity of slurry in the mill at the point of trunnion overflow is determined by the mill dimensions and charge geometry. The [[Ball Mill (Overfilling)#Shi|method described by Shi (2016)]] is used to compute the volumetric sum of slurry within the charge void space and slurry pool at the overflow condition.{{Shi_(2016)}} | ||
The model computes the value of <math>d_{max}</math> to ensure the total flow rate of water plus solids classified for discharge matches the required product pulp outflow rate (i.e. the feed rate) for an overflow mill. | The model computes the value of <math>d_{\rm max}</math> to ensure the total flow rate of water plus solids classified for discharge matches the required product pulp outflow rate (i.e. the feed rate) for an overflow mill. | ||
==== Grate discharge mill ==== | ==== Grate discharge mill ==== | ||
Line 196: | Line 90: | ||
{{Model theory (Text, Slurry Flow, Morrell and Stephenson)}} | {{Model theory (Text, Slurry Flow, Morrell and Stephenson)}} | ||
The model computes the value of <math>d_{max}</math> to ensure the flow rate of water and solids <math>< | The model computes the value of <math>d_{\rm max}</math> to ensure the flow rate of water and solids <math><x_{\rm m}</math> discharged from the mill matches the flow rate required by the Morrell and Stephenson relations at the current slurry hold-up level. | ||
If the mill continues to fill due to excessive feed rate or insufficient discharge capacity, the slurry level will eventually overflow the trunnion lip (filling state 4). Once this occurs, the overflow discharge method described above is used to determine pulp outflow (i.e. <math>d_{max}</math> computed such that mill discharge flow rate = mill feed flow rate). | If the mill continues to fill due to excessive feed rate or insufficient discharge capacity, the slurry level will eventually overflow the trunnion lip (filling state 4). Once this occurs, the overflow discharge method described above is used to determine pulp outflow (i.e. <math>d_{\rm max}</math> computed such that mill discharge flow rate = mill feed flow rate). | ||
=== Power draw=== | === Power draw=== | ||
Line 219: | Line 113: | ||
This makes the Hilden and Powell model it a convenient formulation for use by the dynamic Perfect Mixing mill model, which is continuously computing the total volume of slurry in the mill during simulation. | This makes the Hilden and Powell model it a convenient formulation for use by the dynamic Perfect Mixing mill model, which is continuously computing the total volume of slurry in the mill during simulation. | ||
== Additional notes == | === Additional notes === | ||
The Leung classification function applies for both grate and overflow discharge mills:{{Leung et al. (1987)}}{{Man_(2001)}} | The Leung classification function applies for both grate and overflow discharge mills:{{Leung et al. (1987)}}{{Man_(2001)}} | ||
* Grate mills are specified according to the aperture dimensions of installed discharge grates. | * Grate mills are specified according to the aperture dimensions of installed discharge grates. | ||
* For overflow mills, the maximum particle size reporting to product may be an appropriate estimate of <math> | * For overflow mills, the maximum particle size reporting to product may be an appropriate estimate of <math>x_{\rm g}</math> if mill contents are not available. | ||
* Alternatively, overflow mills may be simplified and classification effects ignored by setting <math>C_i=1</math> for all <math>i</math>, if preferred. | * Alternatively, overflow mills may be simplified and classification effects ignored by setting <math>C_i=1</math> for all <math>i</math>, if preferred. | ||
* A value of 1 mm for <math> | * A value of 1 mm for <math>x_{\rm m}</math> may be an adequate choice for both mill discharge configurations. | ||
</hide> | |||
== Excel == | == Excel == | ||
Line 247: | Line 142: | ||
:<math>Parameters= | :<math>Parameters= | ||
\begin{bmatrix} | \begin{bmatrix} | ||
D_{Orig}\text{ (m)}\\ | D_{\rm Orig}\text{ (m)}\\ | ||
{\rm LF}_{\rm Orig}\text{ (v/v)}\\ | |||
(C_{\rm s})_{\rm Orig}\text{ (frac)}\\ | |||
{\rm WI}_{\rm Orig}\text{ (kWh/t)}\\ | |||
Db_{Orig}\text{ (mm)}\\ | Db_{\rm Orig}\text{ (mm)}\\ | ||
D_{Sim}\text{ (m)}\\ | D_{\rm Sim}\text{ (m)}\\ | ||
{\rm LF}_{\rm Sim}\text{ (v/v)}\\ | |||
(C_{\rm s})_{\rm Sim}\text{ (frac)}\\ | |||
{\rm WI}_{\rm Orig}\text{ (kWh/t)}\\ | |||
Db_{Sim}\text{ (mm)}\\ | Db_{\rm Sim}\text{ (mm)}\\ | ||
K\\ | K\\ | ||
L\text{ (m)}\\ | L\text{ (m)}\\ | ||
\alpha_{c}\text{ (deg.)}\\ | \alpha_{c}\text{ (deg.)}\\ | ||
D_{\rm t}\text{ (m)}\\ | |||
J_{\rm B}\text{ (v/v)}\\ | |||
U\text{ (v/v)}\\ | U\text{ (v/v)}\\ | ||
\ | \rho_{\rm B}\text{ (t/m}^{\text{3}}\text{)}\\ | ||
(Q_{M,F})_{ | (Q_{\rm M,F})_{\rm L}\text{ (t/h)}\\ | ||
\ | \rho_{\rm L}\text{ (t/m}^{\text{3}}\text{)}\\ | ||
\text{Classification method}\\ | \text{Classification method}\\ | ||
x_{\rm m} \text{ (mm)}\\ | |||
\text{Discharge type}\\ | \text{Discharge type}\\ | ||
A\text{ (m}^{\text{2}}\text{)}\\ | A\text{ (m}^{\text{2}}\text{)}\\ | ||
\gamma \text{ (m/m)}\\ | \gamma \text{ (m/m)}\\ | ||
r_{\rm n} \text{ (m/m)}\\ | |||
k_{\rm m}\\ | |||
k_{\rm t}\\ | |||
\text{User overflow volume (m}^{\text{3}}\text{)}\\ | \text{User overflow volume (m}^{\text{3}}\text{)}\\ | ||
\end{bmatrix},\;\;\;\;\;\; | \end{bmatrix},\;\;\;\;\;\; | ||
Line 284: | Line 179: | ||
MillFeed= \begin{bmatrix} | MillFeed= \begin{bmatrix} | ||
(Q_{M,F})_{11}\text{ (t/h)} & \dots & (Q_{M,F})_{1m}\text{ (t/h)}\\ | (Q_{\rm M,F})_{11}\text{ (t/h)} & \dots & (Q_{\rm M,F})_{1m}\text{ (t/h)}\\ | ||
\vdots & \ddots & \vdots\\ | \vdots & \ddots & \vdots\\ | ||
(Q_{M,F})_{n1}\text{ (t/h)} & \dots & (Q_{M,F})_{nm}\text{ (t/h)}\\ | (Q_{\rm M,F})_{n1}\text{ (t/h)} & \dots & (Q_{\rm M,F})_{nm}\text{ (t/h)}\\ | ||
\end{bmatrix},\;\;\;\;\;\; | \end{bmatrix},\;\;\;\;\;\; | ||
OreSG= \begin{bmatrix} | OreSG= \begin{bmatrix} | ||
(\rho_{\rm S})_{1}\text{ (t/m}^\text{3}\text{)} & \dots & (\rho_{\rm S})_m\text{ (t/m}^\text{3}\text{)}\\ | |||
\end{bmatrix} | \end{bmatrix} | ||
</math> | </math> | ||
Line 309: | Line 204: | ||
\end{bmatrix},\;\;\;\;\;\; | \end{bmatrix},\;\;\;\;\;\; | ||
{\rm WI}_{\rm Sim}= \begin{bmatrix} | |||
{\rm WI}_{1}\text{ (kWh/t)} & \dots & {\rm WI}_m\text{ (kWh/t)}\\ | |||
\end{bmatrix},\;\;\;\;\;\; | \end{bmatrix},\;\;\;\;\;\; | ||
Line 332: | Line 227: | ||
\vdots\\ | \vdots\\ | ||
C_{31}\text{ (frac)}\\ | C_{31}\text{ (frac)}\\ | ||
\end{bmatrix} & \mbox{if | \end{bmatrix} & \mbox{if Classification method}=0\mbox{ (User)}\\ | ||
x_{\rm g} & \mbox{if Classification method}=1\mbox{ (Leung)}\\ | |||
\end{cases} | \end{cases} | ||
</math> | </math> | ||
Line 340: | Line 235: | ||
* <math>L</math> is the mill (belly) length | * <math>L</math> is the mill (belly) length | ||
* <math>\alpha_{c}</math> is angle between the cone end surface and the vertical direction (degrees) | * <math>\alpha_{c}</math> is angle between the cone end surface and the vertical direction (degrees) | ||
* <math> | * <math>D_{\rm t}</math> is the diameter of the discharge trunnion (m) | ||
* <math> | * <math>J_{\rm B}</math> is the ball charge volume fraction (often <math>J_{\rm B} = {\rm LF}</math>) (v/v) | ||
* <math>U</math> is the void fill fraction, the volumetric fraction of grinding media interstitial void space occupied by slurry (v/v) | * <math>U</math> is the void fill fraction, the volumetric fraction of grinding media interstitial void space occupied by slurry (v/v) | ||
* <math>\ | * <math>\rho_{\rm B}</math> is the Specific Gravity or density of the ball media (excluding void space) (- or t/m<sup>3</sup>) | ||
* <math>(Q_{M,F})_{ | * <math>(Q_{\rm M,F})_{\rm L}</math> is the mass flow feed rate of liquids into the mill (t/h) | ||
* <math>\ | * <math>\rho_{\rm L}</math> is the Specific Gravity or density of liquids in the feed (- or t/m<sup>3</sup>) | ||
* <math>\text{Classification method }</math> is the method used to defined the classification-by-size to discharge, ''0 = User-defined partition'' or ''1 = Leung method'' | * <math>\text{Classification method }</math> is the method used to defined the classification-by-size to discharge, ''0 = User-defined partition'' or ''1 = Leung method'' | ||
* <math>\text{Discharge type}</math> is discharge configuration, ''0 = Grate discharge, 1 = Overflow discharge at trunnion height, 2 = Overflow discharge at user-defined slurry filling volume'' | * <math>\text{Discharge type}</math> is discharge configuration, ''0 = Grate discharge, 1 = Overflow discharge at trunnion height, 2 = Overflow discharge at user-defined slurry filling volume'' | ||
* <math>\text{User overflow volume}</math> is the user-specified slurry filling volume at which overflow commences (if <math>\text{Discharge type}=2</math>) (m<sup>3</sup>) | * <math>\text{User overflow volume}</math> is the user-specified slurry filling volume at which overflow commences (if <math>\text{Discharge type}=2</math>) (m<sup>3</sup>) | ||
* <math>m</math> is the number of ore types | * <math>m</math> is the number of ore types | ||
* <math>k</math> is the number of breakage rate per discharge rate knots | * <math>k</math> is the number of breakage rate per discharge rate knots | ||
* <math>Q_{M,F}</math> is feed mass flow rate (t/h) | * <math>Q_{\rm M,F}</math> is feed mass flow rate (t/h) | ||
* <math> | * <math>\rho_{\rm S}</math> is Specific Gravity or density (- or t/m<sup>3</sup>) | ||
=== Results === | === Results === | ||
Line 364: | Line 258: | ||
\begin{bmatrix} | \begin{bmatrix} | ||
\text{ | Q_{\rm V,F}\text{ (m}^{\text{3}}\text{/h)}\\ | ||
\text{ | V\text{ (m}^{\text{3}}\text{)}\\ | ||
\text{ | N\text{ (rpm)}\\ | ||
f_D\text{ (-)}\\ | |||
f_{\rm LF}\text{ (-)}\\ | |||
f_{\rm CS}\text{ (-)}\\ | |||
x_{\rm m(small)}\text{ (mm)}\\ | |||
x_{\rm m(large)}\text{ (mm)}\\ | |||
\text{Iterations}\\ | \text{Iterations}\\ | ||
dt\text{ (s)}\\ | dt\text{ (s)}\\ | ||
d_{max}\text{ (h}^{\text{-1}}\text{)}\\ | d_{\rm max}\text{ (h}^{\text{-1}}\text{)}\\ | ||
\text{Ore mass (t)}\\ | \text{Ore mass (t)}\\ | ||
\text{Liquid mass (t)}\\ | \text{Liquid mass (t)}\\ | ||
Line 382: | Line 276: | ||
\text{Max. slurry in mill (OF) (m}^{\text{3}}\text{)}\\ | \text{Max. slurry in mill (OF) (m}^{\text{3}}\text{)}\\ | ||
U\text{ (frac)}\\ | U\text{ (frac)}\\ | ||
(Q_{M,P})_{ | (Q_{\rm M,P})_{\rm L}\text{ (t/h)}\\ | ||
J_{pg}\text{ (v/v)}\\ | J_{\rm pg}\text{ (v/v)}\\ | ||
J_{po}\text{ (v/v)}\\ | J_{\rm po}\text{ (v/v)}\\ | ||
J_{max}\text{ (v/v)}\\ | J_{\rm max}\text{ (v/v)}\\ | ||
J_{\rm p}\text{ (v/v)}\\ | |||
J_{pm}\text{ (v/v)}\\ | J_{\rm pm}\text{ (v/v)}\\ | ||
J_{pt}\text{ (v/v)}\\ | J_{\rm pt}\text{ (v/v)}\\ | ||
Q_\text{m}\text{ (m}^{\text{3}}\text{/h)}\\ | Q_\text{m}\text{ (m}^{\text{3}}\text{/h)}\\ | ||
Q_{\rm t}\text{ (m}^{\text{3}}\text{/h)}\\ | |||
Q\text{ (m}^{\text{3}}\text{/h)}\\ | Q\text{ (m}^{\text{3}}\text{/h)}\\ | ||
\end{bmatrix} | \end{bmatrix} | ||
Line 407: | Line 301: | ||
\begin{bmatrix} | \begin{bmatrix} | ||
(Q_{M,P})_{11}\text{ (t/h)} & \dots & (Q_{M,P})_{1m}\text{ (t/h)}\\ | (Q_{\rm M,P})_{11}\text{ (t/h)} & \dots & (Q_{\rm M,P})_{1m}\text{ (t/h)}\\ | ||
\vdots & \ddots & \vdots\\ | \vdots & \ddots & \vdots\\ | ||
(Q_{M,P})_{n1}\text{ (t/h)} & \dots & (Q_{M,P})_{nm}\text{ (t/h)}\\ | (Q_{\rm M,P})_{n1}\text{ (t/h)} & \dots & (Q_{\rm M,P})_{nm}\text{ (t/h)}\\ | ||
\end{bmatrix} | \end{bmatrix} | ||
Line 473: | Line 367: | ||
\begin{bmatrix} | \begin{bmatrix} | ||
( | (f_{\rm WI})_1 & \dots & (f_{\rm WI})_m | ||
\end{bmatrix}\\ | \end{bmatrix}\\ | ||
Line 504: | Line 398: | ||
where: | where: | ||
* <math>\ | * <math>Q_{\rm V,f}</math> is the flow rate of pulp into the mill (m<sup>3</sup>/h) | ||
* <math> | * <math>V</math> is the total volume inside the mill, calculated as the sum of a cylinder and two frustums (m<sup>3</sup>) | ||
* <math> | * <math>N</math> is the [[Tumbling Mill (Speed)|rotational rate of the mill]] (rpm) | ||
* <math>\text{Iterations}</math> is the number of time steps required to reach steady-state | * <math>\text{Iterations}</math> is the number of time steps required to reach steady-state | ||
* <math>dt</math> is the size of the discretised time step calculated by the model, <math>\Delta t</math> (s) | * <math>dt</math> is the size of the discretised time step calculated by the model, <math>\Delta t</math> (s) | ||
Line 515: | Line 409: | ||
* <math>\text{Max. slurry in charge}</math> is the maximum volume of slurry that can occupy the charge void space before forming a slurry pool (m<sup>3</sup>) | * <math>\text{Max. slurry in charge}</math> is the maximum volume of slurry that can occupy the charge void space before forming a slurry pool (m<sup>3</sup>) | ||
* <math>\text{Max. slurry in mill (OF)}</math> is the maximum volume of slurry in the mill before trunnion overflow commences (m<sup>3</sup>) | * <math>\text{Max. slurry in mill (OF)}</math> is the maximum volume of slurry in the mill before trunnion overflow commences (m<sup>3</sup>) | ||
* <math>(Q_{M, | * <math>(Q_{\rm M,P})_{\rm L}</math> is the discharge mass flow rate of liquids from the mill (t/h) | ||
* <math>Q_{M,P}</math> is product mass flow rate (t/h) | * <math>Q_{\rm M,P}</math> is product mass flow rate (t/h) | ||
* <math>M</math> is the mass of solids in the mill (t) | * <math>M</math> is the mass of solids in the mill (t) | ||
Line 526: | Line 420: | ||
|- style="vertical-align:top;" | |- style="vertical-align:top;" | ||
| [[File:BallMillPerfectMixingDynamic7.png|left|frame|Figure 5. Example showing the selection of the '''Parameters''' (blue frame) array in Excel.]] | | [[File:BallMillPerfectMixingDynamic7.png|left|frame|Figure 5. Example showing the selection of the '''Parameters''' (blue frame) array in Excel.]] | ||
| [[File:BallMillPerfectMixingDynamic8.png|left|frame|Figure 6. Example showing the selection of the '''Appearance''' (pink frame), '''RKnotPositions''' (teal frame), '''RKnotsOrig''' (blue frame), '''WorkIndexSim''' (dark red frame), '''Classification''' (Leung, <math> | | [[File:BallMillPerfectMixingDynamic8.png|left|frame|Figure 6. Example showing the selection of the '''Appearance''' (pink frame), '''RKnotPositions''' (teal frame), '''RKnotsOrig''' (blue frame), '''WorkIndexSim''' (dark red frame), '''Classification''' (Leung, <math>x_{\rm g}</math>) (red frame) arrays in Excel.]] | ||
|} | |} | ||
{| | {| | ||
Line 538: | Line 432: | ||
The SysCAD interface for Dynamic mode is described below. For steady-state, see ''[[Ball Mill (Perfect Mixing)]]''. | The SysCAD interface for Dynamic mode is described below. For steady-state, see ''[[Ball Mill (Perfect Mixing)]]''. | ||
{{SysCAD (Page, | {{SysCAD (Page, Mill, DLL*Mill)|PowerModels=true|MediaTraj=true|MediaStrings=true|Overfilling=true}} | ||
{{SysCAD (Page, Ball Mill, Perfect Mixing, Mill)|method=1}} | {{SysCAD (Page, Ball Mill, Perfect Mixing, Mill)|method=1}} | ||
{{SysCAD (Page, Ball Mill, Perfect Mixing, Ore)}} | {{SysCAD (Page, Ball Mill, Perfect Mixing, Ore)|method=Ball}} | ||
{{SysCAD (Page, Ball Mill, Perfect Mixing, Ri/Di)|method=1}} | {{SysCAD (Page, Ball Mill, Perfect Mixing, Ri/Di)|method=1}} | ||
{{SysCAD (Page, Tumbling Mill, Power)|modelpage= | {{SysCAD (Page, Ball Mill, Perfect Mixing, Load)}} | ||
{{SysCAD (Page, Ball Mill, Perfect Mixing, Content)}} | |||
{{SysCAD (Page, Tumbling Mill, Power)|modelpage={{SysCAD (Text, UnitType Prefix)}}Mill|HildenPowell=true}} | |||
{{SysCAD (Page, Tumbling Mill, MediaStrings)|modelpage={{SysCAD (Text, UnitType Prefix)}}Mill}} | |||
{{SysCAD (Page, Tumbling Mill, MediaTraj)|modelpage= | {{SysCAD (Page, Tumbling Mill, MediaTraj)|modelpage={{SysCAD (Text, UnitType Prefix)}}Mill}} | ||
{{SysCAD (Page, | {{SysCAD (Page, Ball Mill, Overfilling)|modelpage={{SysCAD (Text, UnitType Prefix)}}Mill}} | ||
{{SysCAD (Page, About)}} | {{SysCAD (Page, About)}} | ||
Line 557: | Line 457: | ||
* [[Ball Mill (Perfect Mixing)|Steady-state Perfect Mixing ball mill model]] | * [[Ball Mill (Perfect Mixing)|Steady-state Perfect Mixing ball mill model]] | ||
* [[ | * [[Mill (Herbst-Fuerstenau)| Herbst-Fuerstenau mill model]] | ||
== References == | == References == | ||
Line 563: | Line 463: | ||
[[Category:Excel]] | [[Category:Excel]] | ||
[[Category:SysCAD]] | [[Category:SysCAD]] | ||
[[Category:Dynamic]] |
Latest revision as of 10:49, 4 December 2024
Description
This article describes a dynamic implementation of the Perfect Mixing ball mill model outlined by Napier-Munn et al. (1996).[1]
The dynamic version uses the same underlying theory and structure as the steady-state Perfect Mixing ball mill model. For a full description of the steady-state model, see Ball Mill (Perfect Mixing).
Model theory
This content is available to registered users. Please log in to view. |
Excel
The Perfect Mixing ball mill model is not implemented in Excel in dynamic form for practical purposes. Excel is not an ideal platform for dynamic simulation and SysCAD (or similar) is preferred.
The dynamic model is, however, included in Excel in a run-to-steady-state mode where all feed and input parameters are fixed and time steps are progressed until the computed load and discharge stabilises.
This mode is useful for extracting separated and functions from steady-state data such as plant surveys or other model calibrations (including the steady-state Perfect Mixing ball mill model).
The run-to-steady-state dynamic Perfect Mixing ball mill model may be invoked from the Excel formula bar with the following function call:
=mdUnit_BallMill_PerfectMixingRiDi(Parameters as Range, Size as Range, MillFeed as Range, OreSG As Range, Appearance as Range, WorkIndexSim as Range, RKnotPositions as Range, RKnotsOrig as Range, Classification as Range)
Invoking the function with no arguments will print Help text associated with the model, including a link to this page.
Inputs
The required inputs are defined below in matrix notation with elements corresponding to cells in Excel row () x column () format:
where:
- is the mill (belly) length
- is angle between the cone end surface and the vertical direction (degrees)
- is the diameter of the discharge trunnion (m)
- is the ball charge volume fraction (often ) (v/v)
- is the void fill fraction, the volumetric fraction of grinding media interstitial void space occupied by slurry (v/v)
- is the Specific Gravity or density of the ball media (excluding void space) (- or t/m3)
- is the mass flow feed rate of liquids into the mill (t/h)
- is the Specific Gravity or density of liquids in the feed (- or t/m3)
- is the method used to defined the classification-by-size to discharge, 0 = User-defined partition or 1 = Leung method
- is discharge configuration, 0 = Grate discharge, 1 = Overflow discharge at trunnion height, 2 = Overflow discharge at user-defined slurry filling volume
- is the user-specified slurry filling volume at which overflow commences (if ) (m3)
- is the number of ore types
- is the number of breakage rate per discharge rate knots
- is feed mass flow rate (t/h)
- is Specific Gravity or density (- or t/m3)
Results
The results are displayed in Excel as an array corresponding to the matrix notation below:
where:
- is the flow rate of pulp into the mill (m3/h)
- is the total volume inside the mill, calculated as the sum of a cylinder and two frustums (m3)
- is the rotational rate of the mill (rpm)
- is the number of time steps required to reach steady-state
- is the size of the discretised time step calculated by the model, (s)
- is the total mass of ore in the mill at steady-state (t)
- is the mass of liquids in the mill at steady-state (t)
- is the mass of balls in the mill at steady-state (t)
- is the volume of slurry in the mill at steady-state (m3)
- is the maximum volume of slurry that can occupy the charge void space before forming a slurry pool (m3)
- is the maximum volume of slurry in the mill before trunnion overflow commences (m3)
- is the discharge mass flow rate of liquids from the mill (t/h)
- is product mass flow rate (t/h)
- is the mass of solids in the mill (t)
Example
The images below show the selection of input arrays and output results in the Excel interface.
SysCAD
The SysCAD interface for Dynamic mode is described below. For steady-state, see Ball Mill (Perfect Mixing).
MD_Mill page
The first tab page in the access window will have this name.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Tag | Display | This name tag may be modified with the change tag option. |
Condition | Display | OK if no errors/warnings, otherwise lists errors/warnings. |
ConditionCount | Display | The current number of errors/warnings. If condition is OK, returns 0. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.
If this field is blank, then SysCAD will display the unit class ID. |
Requirements | ||
On | CheckBox | This enables the unit. If this box is not checked, then the material will pass straight through the mill with no change to the size distribution. |
NumParallelUnits | Input | The number of parallel, identical units to simulate:
|
Method | Fixed Discharge | The discharge particle size distribution is user defined. Different distributions can be used for different solids. |
AG/SAG (Variable Rates) | The Variable Rates AG/SAG mill model is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
Rod Mill (Lynch) | The Lynch rod mill model is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
Ball (Perfect Mixing) | The Perfect Mixing ball mill model (steady-state or dynamic) is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
Stirred (Perfect Mixing) | The Perfect Mixing stirred mill model (steady-state or dynamic) is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
Mill (Herbst-Fuerstenau) | The Herbst-Fuerstenau model is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
PowerModels | CheckBox | Show alternative mill power model calculations on the Power page. |
MediaTrajectory | CheckBox | Show mill media rolling, sliding and free flight trajectory computations on the MediaTraj page. |
OverfillingIndicator | CheckBox | Show overflow ball mill slurry volume, residence time, and overfilling evaluation on Overfilling page. |
MediaStrings | CheckBox | Show media size distributions at recharge equilibrium on the MediaStrings page. |
Options | ||
ShowQFeed | CheckBox | QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream. |
ShowQProd | CheckBox | QProd and associated tab pages (eg Sp) will become visible, showing the properties of the products. |
SizeForPassingFracCalc | Input | Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section. |
FracForPassingSizeCalc | Input | Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section. |
Stream Summary | ||
MassFlow / Qm | Display | The total mass flow in each stream. |
SolidMassFlow / SQm | Display | The Solids mass flow in each stream. |
LiquidMassFlow / LQm | Display | The Liquid mass flow in each stream. |
VolFlow / Qv | Display | The total Volume flow in each stream. |
Temperature / T | Display | The Temperature of each stream. |
Density / Rho | Display | The Density of each stream. |
SolidFrac / Sf | Display | The Solid Fraction in each stream. |
LiquidFrac / Lf | Display | The Liquid Fraction in each stream. |
Passing | Display | The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream. |
Passes | Display | The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction. |
Mill page
The Mill page is used to specify the input parameters for the mill model.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
PerfectMixing | ||
HelpLink | Opens a link to this page using the system default web browser. Note: Internet access is required. | |
Mode | Steady State |
|
Dynamic | The dynamic Perfect Mixing ball mill model described here is used to determine the mill product size distribution. Different parameters can be used for different solids. | |
MinSubSteps | Input | The user-specified minimum number of internal models steps taken per SysCAD step. |
SubSteps | Display | The actual number of internal models steps taken per SysCAD step. May be affected by breakage/discharge rates or the user-specified MinSubSteps parameter. |
DischargeType | Grate | The ball mill is configured with a grate discharge. |
Overflow | The ball mill is configured with an overflow discharge. The maximum slurry volume in the mill before overflowing the trunnion is calculated by the model. | |
Overflow (User) | The ball mill is configured with an overflow discharge. The user specifies the maximum slurry volume before overflow. | |
Ball | ||
MediaStringsP50 | CheckBox |
|
Diameter | Input | The inside liner diameter of the original and simulated ball mills. |
BellyLength | Input | The inside liner belly length of the simulated ball mill, excluding cones. |
ConeAngle | Input | Angle of the feed and discharge end cones, measured as positive displacement from the vertical direction. |
TrunnionDiameter | Input | The inside liner trunnion diameter of the simulated ball mill. |
LoadFrac | Input | The volumetric load fraction of the original and simulated ball mills. |
FracCS | Input | The fraction critical speed of the original and simulated ball mills. |
WorkIndex | Input | Bond Ball Work Index of ore in the original mill. |
BallSize | Input | Characteristic diameter of balls in original and simulated ball mills. |
MaxBreakageRateFactor / K | Input | Parameter relating ball size and the size at which the breakage rate per discharge rate is maximum. |
RFunction | ||
NumSplineKnots | Input | Number of spline knots for the function. |
Size | Input | Spline knot size positions. |
Ln(R) | Input | Values of at each spline knot position. |
Power | ||
BallVolume | Input | Volumetric fraction of mill occupied by balls and voids. |
VoidFillFraction | Input | Volumetric fraction of void space between balls occupied by slurry. |
BallSG | Input | Specific Gravity or density of ball media. |
Results | ||
MillVolume | Display | Volume inside mill, including cones. |
MillSpeed | Display | Rotational speed of simulated mill. |
Ore page
This page is used to define the comminution properties of SysCAD species with the size distribution quality in the project.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Appearance | ||
DefaultAppearance | Sets all species to the the default Broadbent-Callcott Appearance function. | |
OreSpecific | CheckBox |
|
Appearance | Input | User-specified Appearance function data for all species with size distribution property. |
WorkIndex | ||
WorkIndex.Sim | Input | Bond Ball Work Index data for all species with size distribution property. |
RiDi page
This page displays the scaling factors and breakage rate per discharge rate for each size interval computed by the Perfect Mixing model.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Scaling | ||
Diameter | Display | Value of the mill diameter factor for rate scaling. |
LoadFraction | Display | Value of the load fraction factor for rate scaling. |
FracCS | Display | Value of the fraction critical speed factor for rate scaling. |
WorkIndex | Display | Value of the Work Index factor of each ore species for rate scaling. |
Rates | ||
Size | Display | Size of each interval in internal mesh series. |
MeanSize | Display | Geometric mean size of each interval in internal mesh series. |
R | Display | Value of breakage rate, , for each size interval, for each ore species. |
C | Display | Value of classification function, , for each size interval. |
D | Display | Value of discharge rate, , for each size interval. |
Load page
This page displays information about the balls, solids and liquids that currently comprise the mill load.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Filling | ||
SLCapacity / SLVtCap | Input / Display | The maximum volume of slurry the mill can contain before overflow. |
SLCharge / SLVtCharge | Display | Only appears if DischargeType is 'Overflow'. The maximum volume of slurry that can fill the charge void space. |
SLVolume / SLVt | Display | The total volume of slurry currently in the mill. |
SLLevel / SLLvl | Display | The current slurry volume (SLVolume) as a fraction of the maximum slurry volume before overflow (SLCapacity). |
Load | ||
SolidMass / SMt | Display | The mass of solids with the SysCAD size distribution property currently in the mill. |
LiquidMass / LMt | Display | The mass of liquids plus solids without the SysCAD size distribution property currently in the mill. |
BallMass / BMt | Display | The mass of ball media in the mill. |
Size | Display | Size of each interval in internal mesh series. |
MeanSize | Display | Geometric mean size of each interval in internal mesh series. |
Load | Display | The mass of solids with the SysCAD size distribution property currently in the mill, by size and species. |
Content, Sp, Ec, Sz and MSz pages
These pages display the standard SysCAD Material Content, Species Content and Size pages for the current mill load
Power page
This optional page displays the inputs and results for alternative mill power models. The page is only visible if PowerModels is selected on the MD_Mill page.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Power | ||
HildenPowell | CheckBox | Shows inputs and results for tumbling mill power calculations using the Hilden and Powell method. |
MediaStrings page
This page displays the inputs and results for grinding mill media string calculations. The page is only visible if MediaStrings is selected on the MD_Mill page.
MediaTraj page
This page displays the inputs and results for tumbling mill media trajectory calculations. The page is only visible if MediaTrajectory is selected on the MD_Mill page.
Overfilling page
This page displays the inputs and results for overflow discharge mill overfilling calculations. The page is only visible if OverfillingIndicator is selected on the MD_Mill page.
About page
This page is provides product and licensing information about the Met Dynamics Models SysCAD Add-On.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
About | ||
HelpLink | Opens a link to the Installation and Licensing page using the system default web browser. Note: Internet access is required. | |
Information | Copies Product and License information to the Windows clipboard. | |
Product | ||
Name | Display | Met Dynamics software product name |
Version | Display | Met Dynamics software product version number. |
BuildDate | Display | Build date and time of the Met Dynamics Models SysCAD Add-On. |
License | ||
File | This is used to locate a Met Dynamics software license file. | |
Location | Display | Type of Met Dynamics software license or file name and path of license file. |
SiteCode | Display | Unique machine identifier for license authorisation. |
ReqdAuth | Display | Authorisation level required, MD-SysCAD Full or MD-SysCAD Runtime. |
Status | Display | License status, LICENSE_OK indicates a valid license, other messages report licensing errors. |
IssuedTo | Display | Only visible if Met Dynamics license file is used. Name of organisation/seat the license is authorised to. |
ExpiryDate | Display | Only visible if Met Dynamics license file is used. License expiry date. |
DaysLeft | Display | Only visible if Met Dynamics license file is used. Days left before the license expires. |
See also
References
- ↑ Napier-Munn, T.J., Morrell, S., Morrison, R.D. and Kojovic, T., 1996. Mineral comminution circuits: their operation and optimisation. Julius Kruttschnitt Mineral Research Centre, Indooroopilly, QLD.