Partition (Size, Reid-Plitt): Difference between revisions

From Met Dynamics
Jump to navigation Jump to search
imported>Scott.Munro
imported>Scott.Munro
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
== Model theory ==
== Model theory ==


{{Restricted content}}
<hide>
[[File:PartitionReidPlitt1.png|thumb|450px|Figure 1. Reid-Plitt partition to underflow with values of <math>{d_{50 \rm c}} = 1.0 \text{ (mm)}</math>,  <math>m = 1.5</math>, and  <math>{R_{\rm f}} = 0.2 \text{ (frac)}</math>.]]
[[File:PartitionReidPlitt1.png|thumb|450px|Figure 1. Reid-Plitt partition to underflow with values of <math>{d_{50 \rm c}} = 1.0 \text{ (mm)}</math>,  <math>m = 1.5</math>, and  <math>{R_{\rm f}} = 0.2 \text{ (frac)}</math>.]]


Line 10: Line 13:


Plitt (1971) found the value of <math>m</math> was in the range of 1 - 3.8.{{Plitt (1971)}}
Plitt (1971) found the value of <math>m</math> was in the range of 1 - 3.8.{{Plitt (1971)}}
</hide>


== Excel ==
== Excel ==
Line 62: Line 66:
== SysCAD ==
== SysCAD ==


The Reid-Plitt partition is available from the '''{{Name (Text, Company Name)|nospace=1}}*Screen''' and '''{{Name (Text, Company Name)|nospace=1}}*Hydrocyclone''' unit models.
The Reid-Plitt partition is available from the '''{{Name (Text, Company Name)|nospace=1}}*Screen''', '''{{Name (Text, Company Name)|nospace=1}}*Hydrocyclone''', amd '''{{Name (Text, Company Name)|nospace=1}}*Classifier''' unit models.


The sections and variable names used in the SysCAD interface are described in detail in the following tables.
The sections and variable names used in the SysCAD interface are described in detail in the following tables.
Line 80: Line 84:
{{SysCAD (Text, Help Link)}}
{{SysCAD (Text, Help Link)}}


|- style="vertical-align:top;"
|OreSpecific
|CheckBox
|
* Ore-specific partitions, allows the Reid-Plitt equation parameters to be separately input for all species.
* Default is all species have the same set of single input properties.
* This option is only available if there is more than one species in the project with the size distribution property.
|-
|-
|d50c
! colspan="3" style="text-align:left;" |''ReidPlitt''
|Input
 
|The Reid-Plitt equation d50c corrected cut size parameter.
{{SysCAD (Text, Partition, Reid-Plitt)}}
|-
|m
|Input
|The Reid-Plitt equation sharpness parameter.
|-
|Rf
|Input
|The Reid-Plitt equation recovery of fines/water to underflow parameter.


{{SysCAD (Text, Screen, Liquids)|method=1}}
{{SysCAD (Text, Screen, Liquids)|method=1}}
Line 119: Line 108:
{{SysCAD (Text, Help Link)}}
{{SysCAD (Text, Help Link)}}


|- style="vertical-align:top;"
{{SysCAD (Text, Partition, Reid-Plitt)}}
|OreSpecific
|CheckBox
|
* Ore-specific partitions, allows the Reid-Plitt equation parameters to be separately input for all species.
* Default is all species have the same set of single input properties.
* This option is only available if there is more than one species in the project with the size distribution property.
|-
|d50c
|Input
|The Reid-Plitt equation d50c corrected cut size parameter.
|-
|m
|Input
|The Reid-Plitt equation sharpness parameter.
|-
|Rf
|Input
|The Reid-Plitt equation recovery of fines/water to underflow parameter.


{{SysCAD (Text, Hydrocyclone, Liquids)|method=0}}
{{SysCAD (Text, Hydrocyclone, Liquids)|method=0}}
Line 146: Line 117:


{{SysCAD (Page, Hydrocyclone, Roping)|WhitenBeta=true}}
{{SysCAD (Page, Hydrocyclone, Roping)|WhitenBeta=true}}
{{SysCAD (Page, Classifier, DLL*Classifier)}}
==== Classifier page ====
The Classifier page is used to specify the input parameters for the classifier model.
{{SysCAD (Text, Table Header)}}
|-
! colspan="3" style="text-align:left;" |''ReidPlitt''
{{SysCAD (Text, Help Link)}}
{{SysCAD (Text, Partition, Reid-Plitt)}}
{{SysCAD (Text, Hydrocyclone, Liquids)|method=0}}
|}
{{SysCAD (Page, Hydrocyclone, Partition)|ActionU=Partition|ActionL=partition|DestinationU=Underflow|DestinationL=underflow|UnitL=classifier}}


{{SysCAD (Page, About)}}
{{SysCAD (Page, About)}}

Latest revision as of 11:34, 4 December 2024

Description

This article describes the Reid-Plitt expression for the recovery of classifier feed to underflow, independently reported by Reid (1971) and Plitt (1971).[1][2]

Model theory

Nuvola apps important blue.svg.png This content is available to registered users. Please log in to view.

Excel

The Reid-Plitt efficiency curve model may be invoked from the Excel formula bar with the following function call:

=mdPartition_ReidPlitt(MeanSize as Range, d50c as Double, m as double, Rf as Double)

Invoking the function with no arguments will print Help text associated with the model, including a link to this page.

The input parameters and model results are defined below in matrix notation, along with an example image showing the selection of the same cells in the Excel interface:

Figure 2. Example showing the selection of the input parameters (shaded cells), and Results (light blue frame) array in Excel.

SysCAD

The Reid-Plitt partition is available from the MetDynamics*Screen, MetDynamics*Hydrocyclone, amd MetDynamics*Classifier unit models.

The sections and variable names used in the SysCAD interface are described in detail in the following tables.

Note that both a Deck page and a Partition page are provided provided for each connected oversize discharge stream of the screen unit model.

MD_Screen page

The first tab page in the access window will have this name.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.

If this field is blank, then SysCAD will display the unit class ID.

Requirements
On CheckBox This enables the unit. If this box is not checked, then the MassFracToOS option appears below.
MassFracToOS Input Only appears if the On field above is not checked. Specifies the fraction of feed mass that reports to the overflow stream when the model is off.
NumParallelUnits Input The number of parallel, identical units to simulate:
  • Feed is divided by the number of parallel units before being sent to the unit model.
  • Unit model products are multiplied back by the same value and returned to the SysCAD product streams.
  • All unit model result values are shown per parallel unit.
Options
ShowQFeed CheckBox QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream.
SizeForPassingFracCalc Input Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section.
FracForPassingSizeCalc Input Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section.
Stream Summary
MassFlow / Qm Display The total mass flow in each stream.
SolidMassFlow / SQm Display The Solids mass flow in each stream.
LiquidMassFlow / LQm Display The Liquid mass flow in each stream.
VolFlow / Qv Display The total Volume flow in each stream.
Temperature / T Display The Temperature of each stream.
Density / Rho Display The Density of each stream.
SolidFrac / Sf Display The Solid Fraction in each stream.
LiquidFrac / Lf Display The Liquid Fraction in each stream.
Passing Display The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream.
Passes Display The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction.

Deck page

The Deck page is used to specify the required model method and associated input parameters.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Deck
On Checkbox This enables the deck. If off, the feed to this deck passes directly to the next deck (or undersize) without partition.
Method Partition (User) The partition to oversize for each size interval is defined by the user. Different values can be used for different solids.
Partition (Reid-Plitt) The partition to oversize for each size interval is defined by a Reid-Plitt efficiency curve. Different parameters can be used for different solids.
Partition (Whiten-Beta) The partition to oversize for each size interval is defined by a Whiten-Beta efficiency curve. Different parameters can be used for different solids.
Vibrating (Karra) The Karra vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval.
Vibrating (Whiten) The Whiten vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval.
Vibrating (Metso) The Metso vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval.
Fine Wet (Mwale) The Mwale fine wet screen model is used to determine the partition of solids to oversize and undersize for each size interval.
Dewatering (Ng) The Ng dewatering screen model is used to determine the moisture content of oversize material, and the partition of solids to oversize and undersize for each size interval.
HelpLink ButtonModelHelp.png Opens a link to this page using the system default web browser. Note: Internet access is required.
ReidPlitt
OreSpecific CheckBox
  • Ore-specific partitions, allows the Reid-Plitt equation parameters to be separately input for all species.
  • Default is all species have the same set of single input properties.
  • This option is only available if there is more than one species in the project with the size distribution property.
d50c Input The Reid-Plitt equation d50c corrected cut size parameter.
m Input The Reid-Plitt equation sharpness parameter.
Rf Input The Reid-Plitt equation recovery of fines/water to underflow parameter.
Liquids
LiquidsSeparMethod Split To OS (User) Liquids are split to oversize by a user-defined fraction of liquids in the feed.
Split To OS (Rf) Liquids are split to oversize by the Rf fraction specified for the screen model.
OS Solids Fraction Sufficient liquids mass is recovered to the oversize stream to yield the user-defined oversize solids mass fraction value (if possible).
OS Liquids Fraction Sufficient liquids mass is recovered to the oversize stream to yield the user-defined oversize liquids mass fraction value (if possible).
OSSolidsFracReqd / OS.SfReqd Input Required value of the mass fraction of solids in the oversize stream. Only visible if OS Solids Fraction is selected.
OSLiquidsFracReqd / OS.LfReqd Input Required value of the mass fraction of liquids in the oversize stream. Only visible if OS Liquids Fraction is selected.
LiqSplitToOS / OS.LiqSplit Input/Display The fraction of feed liquids recovered to the oversize stream.

Partition page

The Partition page is used to specify or display the partition by species and size values.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Distribution
Name Display Shows the name of the SysCAD Size Distribution (PSD) quality associated with the feed stream.
IntervalCount Display Shows the number of size intervals in the SysCAD Size Distribution (PSD) quality associated with the feed stream.
SpWithPSDCount Display Shows the number of species in the feed stream assigned with the SysCAD Size Distribution (PSD) quality.
Partition
Method Model/User Select model-calculated or user-defined partition to separate each solids species type.
Density Display Density of each solid species.
Size Display Size of each interval in mesh series.
MeanSize Display Geometric mean size of each interval in mesh series.
All (All column) Display
  • Actual overall partition to oversize of all solid species, for each size interval.
  • Excludes solid species not present in the screen feed.
Partition Display
  • Partition to oversize for each size interval, in each solid species, as determined by the selected model or user defined value.
  • Note: These values are displayed regardless of whether the solid species is present in the screen feed or not.
All (All row, All column) Display
  • Displays the actual, total, partition of all solids with a particle size distribution property in the feed to oversize.
  • Excludes solid species not present in the screen feed.
All (All row, per species) Display
  • Actual overall partition to oversize for each solid species, for all size intervals in that species.
  • Excludes solid species not present in the screen feed.

MD_Hydrocyclone page

The first tab page in the access window will have this name.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.

If this field is blank, then SysCAD will display the unit class ID.

Requirements
On CheckBox This enables the unit. If this box is not checked, then the MassFracToUF option appears below.
MassFracToUF Input Only appears if the On field above is not checked. Specifies the fraction of feed mass that reports to the underflow stream when the model is off.
Method Partition (User) The partition to overflow for each size interval is defined by the user. Different values can be used for different solids.
Partition (Reid-Plitt) The partition to overflow for each size interval is defined by a Reid-Plitt efficiency curve. Different parameters can be used for different solids.
Partition (Whiten-Beta) The partition to overflow for each size interval is defined by a Whiten-Beta efficiency curve. Different parameters can be used for different solids.
Nageswararao The Nageswararao model is used to determine the partition of solids to underflow and overflow for each size interval.
Narasimha-Mainza (2014) The Narasimha-Mainza (2014) model is used to determine the partition of solids to underflow and overflow for each size interval.
Narasimha-Mainza (Multi) The Narasimha-Mainza (Multi) model is used to determine the partition of solids to underflow and overflow for each size interval.
Plitt The Plitt model is used to determine the partition of solids to underflow and overflow for each size interval.
RopingCalcs CheckBox Show addition calculations that predict the onset of cyclone underflow roping.
Options
ShowQFeed CheckBox QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream.
ShowQOF CheckBox QOF and associated tab pages (eg Sp) will become visible, showing the properties of the overflow stream.
ShowQUF CheckBox QUF and associated tab pages (eg Sp) will become visible, showing the properties of the underflow stream.
SizeForPassingFracCalc Input Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section.
FracForPassingSizeCalc Input Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section.
Stream Summary
MassFlow / Qm Display The total mass flow in each stream.
SolidMassFlow / SQm Display The Solids mass flow in each stream.
LiquidMassFlow / LQm Display The Liquid mass flow in each stream.
VolFlow / Qv Display The total Volume flow in each stream.
Temperature / T Display The Temperature of each stream.
Density / Rho Display The Density of each stream.
SolidFrac / Sf Display The Solid Fraction in each stream.
LiquidFrac / Lf Display The Liquid Fraction in each stream.
Passing Display The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream.
Passes Display The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction.

Cyclone page

The Cyclone page is used to specify the input parameters for the hydrocyclone model.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
ReidPlitt
HelpLink ButtonModelHelp.png Opens a link to this page using the system default web browser. Note: Internet access is required.
OreSpecific CheckBox
  • Ore-specific partitions, allows the Reid-Plitt equation parameters to be separately input for all species.
  • Default is all species have the same set of single input properties.
  • This option is only available if there is more than one species in the project with the size distribution property.
d50c Input The Reid-Plitt equation d50c corrected cut size parameter.
m Input The Reid-Plitt equation sharpness parameter.
Rf Input The Reid-Plitt equation recovery of fines/water to underflow parameter.
Liquids
LiquidsSeparMethod Split To UF (User) Liquids are split to underflow by a user-defined fraction of liquids in the feed.
Split To UF (Model) Liquids are split to underflow by a fraction computed by the associated model.
UF Solids Fraction Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow solids mass fraction value (if possible).
UF Liquids Fraction Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow liquids mass fraction value (if possible).
UFSolidsFracReqd / UF.SfReqd Input Required value of the mass fraction of solids in the underflow stream. Only visible if UF Solids Fraction is selected.
UFLiquidsFracReqd / UF.LfReqd Input Required value of the mass fraction of liquids in the underflow stream. Only visible if UF Liquids Fraction is selected.
LiqSplitToUF / UF.LiqSplit Input/Display The fraction of liquids recovered to underflow.

Partition page

The Partition page is used to specify or display the partition by species and size values.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Distribution
Name Display Shows the name of the SysCAD Size Distribution (PSD) quality associated with the feed stream.
IntervalCount Display Shows the number of size intervals in the SysCAD Size Distribution (PSD) quality associated with the feed stream.
SpWithPSDCount Display Shows the number of species in the feed stream assigned with the SysCAD Size Distribution (PSD) quality.
Partition
Method Model/User Select model-calculated or user-defined partition to separate each solids species type.
Density Display Density of each solid species.
Size Display Size of each interval in mesh series.
MeanSize Display Geometric mean size of each interval in mesh series.
All (All column) Display
  • Actual overall partition to overflow of all solid species, for each size interval.
  • Excludes solid species not present in the cyclone feed.
Partition Display
  • Partition to overflow for each size interval, in each solid species, as determined by the selected model or user defined value.
  • Note: These values are displayed regardless of whether the solid species is present in the cyclone feed or not.
All (All row, All column) Display
  • Displays the actual, total, partition of all solids with a particle size distribution property in the feed to overflow.
  • Excludes solid species not present in the cyclone feed.
All (All row, per species) Display
  • Actual overall partition to overflow for each solid species, for all size intervals in that species.
  • Excludes solid species not present in the cyclone feed.

Roping page

This page displays the results for hydrocyclone roping limit calculations. The page is only visible if Roping is selected on the MD_Hydrocyclone page.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Roping
Underflow
SolidsVolFrac / Svf Display Volume fraction of solids in the cyclone underflow stream.
SPOC Display SPOC volume fraction of solids in the cyclone underflow roping limit.

MD_Classifier page

The first tab page in the access window will have this name.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.

If this field is blank, then SysCAD will display the unit class ID.

Requirements
On CheckBox This enables the unit. If this box is not checked, then the MassFracToUF option appears below.
MassFracToUF Input Only appears if the On field above is not checked. Specifies the fraction of feed mass that reports to the underflow stream when the model is off.
NumParallelUnits Input The number of parallel, identical units to simulate:
  • Feed is divided by the number of parallel units before being sent to the unit model.
  • Unit model products are multiplied back by the same value and returned to the SysCAD product streams.
  • All unit model result values are shown per parallel unit.
Method Partition (User) The partition to underflow for each size interval is defined by the user. Different values can be used for different solids.
Partition (Reid-Plitt) The partition to underflow for each size interval is defined by a Reid-Plitt efficiency curve. Different parameters can be used for different solids.
Partition (Whiten-Beta) The partition to underflow for each size interval is defined by a Whiten-Beta efficiency curve. Different parameters can be used for different solids.
Air Classifier (Altun) The Altun air classifier model is used to determine the partition of solids to underflow for each size interval.
Gravity (Plitt-Flintoff) The Plitt-Flintoff gravity classifier model is used to determine the partition of solids to underflow for each size interval.
Options
ShowQFeed CheckBox QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream.
ShowQOF CheckBox QOF and associated tab pages (eg Sp) will become visible, showing the properties of the overflow stream.
ShowQUF CheckBox QUF and associated tab pages (eg Sp) will become visible, showing the properties of the underflow stream.
SizeForPassingFracCalc Input Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section.
FracForPassingSizeCalc Input Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section.
Stream Summary
MassFlow / Qm Display The total mass flow in each stream.
SolidMassFlow / SQm Display The Solids mass flow in each stream.
LiquidMassFlow / LQm Display The Liquid mass flow in each stream.
VolFlow / Qv Display The total Volume flow in each stream.
Temperature / T Display The Temperature of each stream.
Density / Rho Display The Density of each stream.
SolidFrac / Sf Display The Solid Fraction in each stream.
LiquidFrac / Lf Display The Liquid Fraction in each stream.
Passing Display The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream.
Passes Display The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction.

Classifier page

The Classifier page is used to specify the input parameters for the classifier model.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
ReidPlitt
HelpLink ButtonModelHelp.png Opens a link to this page using the system default web browser. Note: Internet access is required.
OreSpecific CheckBox
  • Ore-specific partitions, allows the Reid-Plitt equation parameters to be separately input for all species.
  • Default is all species have the same set of single input properties.
  • This option is only available if there is more than one species in the project with the size distribution property.
d50c Input The Reid-Plitt equation d50c corrected cut size parameter.
m Input The Reid-Plitt equation sharpness parameter.
Rf Input The Reid-Plitt equation recovery of fines/water to underflow parameter.
Liquids
LiquidsSeparMethod Split To UF (User) Liquids are split to underflow by a user-defined fraction of liquids in the feed.
Split To UF (Model) Liquids are split to underflow by a fraction computed by the associated model.
UF Solids Fraction Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow solids mass fraction value (if possible).
UF Liquids Fraction Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow liquids mass fraction value (if possible).
UFSolidsFracReqd / UF.SfReqd Input Required value of the mass fraction of solids in the underflow stream. Only visible if UF Solids Fraction is selected.
UFLiquidsFracReqd / UF.LfReqd Input Required value of the mass fraction of liquids in the underflow stream. Only visible if UF Liquids Fraction is selected.
LiqSplitToUF / UF.LiqSplit Input/Display The fraction of liquids recovered to underflow.

Partition page

The Partition page is used to specify or display the partition by species and size values.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Distribution
Name Display Shows the name of the SysCAD Size Distribution (PSD) quality associated with the feed stream.
IntervalCount Display Shows the number of size intervals in the SysCAD Size Distribution (PSD) quality associated with the feed stream.
SpWithPSDCount Display Shows the number of species in the feed stream assigned with the SysCAD Size Distribution (PSD) quality.
Partition
Method Model/User Select model-calculated or user-defined partition to separate each solids species type.
Density Display Density of each solid species.
Size Display Size of each interval in mesh series.
MeanSize Display Geometric mean size of each interval in mesh series.
All (All column) Display
  • Actual overall partition to underflow of all solid species, for each size interval.
  • Excludes solid species not present in the classifier feed.
Partition Display
  • Partition to underflow for each size interval, in each solid species, as determined by the selected model or user defined value.
  • Note: These values are displayed regardless of whether the solid species is present in the classifier feed or not.
All (All row, All column) Display
  • Displays the actual, total, partition of all solids with a particle size distribution property in the feed to underflow.
  • Excludes solid species not present in the classifier feed.
All (All row, per species) Display
  • Actual overall partition to underflow for each solid species, for all size intervals in that species.
  • Excludes solid species not present in the classifier feed.

About page

This page is provides product and licensing information about the Met Dynamics Models SysCAD Add-On.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
About
HelpLink ButtonLicensingHelp.png Opens a link to the Installation and Licensing page using the system default web browser. Note: Internet access is required.
Information ButtonCopyToClipboard.png Copies Product and License information to the Windows clipboard.
Product
Name Display Met Dynamics software product name
Version Display Met Dynamics software product version number.
BuildDate Display Build date and time of the Met Dynamics Models SysCAD Add-On.
License
File ButtonBrowse.png This is used to locate a Met Dynamics software license file.
Location Display Type of Met Dynamics software license or file name and path of license file.
SiteCode Display Unique machine identifier for license authorisation.
ReqdAuth Display Authorisation level required, MD-SysCAD Full or MD-SysCAD Runtime.
Status Display License status, LICENSE_OK indicates a valid license, other messages report licensing errors.
IssuedTo Display Only visible if Met Dynamics license file is used. Name of organisation/seat the license is authorised to.
ExpiryDate Display Only visible if Met Dynamics license file is used. License expiry date.
DaysLeft Display Only visible if Met Dynamics license file is used. Days left before the license expires.

See also

References

  1. Reid, K.J., 1971. Derivation of an equation for classifier-reduced performance curves. Canadian Metallurgical Quarterly, 10(3), pp.253-254.
  2. Plitt, L.R., 1971. The analysis of solid-solid separations in classifiers. CIM bulletin, 64(708), pp.42-47.