Template:SysCAD (Text, HPGR, No PSD Splits)

From Met Dynamics
Jump to navigation Jump to search

When the edge stream is connected, the following applies to mass splits:

  • Solid species without a particle size distribution property are split to the edge stream according to the overall mass split of the default particle size distribution species selected in the SysCAD Project Configuration
  • If the default particle size distribution species is not present in the unit feed, the overall split of all other species with particle size distributions combined is used, as determined by the model.
  • Liquids species are split between the edge and product streams in the same proportion as solid species.
  • Gas phase species report directly to the product stream without split.