Template:SysCAD (Text, HPGR, No PSD Splits): Difference between revisions
Jump to navigation
Jump to search
imported>Scott.Munro (Created page with "When the edge stream is connected, the following applies to mass splits: * Liquids and solid species without a particle size distribution property are split between the edge a...") |
imported>Scott.Munro mNo edit summary |
||
Line 1: | Line 1: | ||
When the edge stream is connected, the following applies to mass splits: | When the edge stream is connected, the following applies to mass splits: | ||
* | * Solid species without a particle size distribution property are split to the edge stream according to the overall mass split of the default particle size distribution species selected in the SysCAD Project Configuration | ||
* If the default particle size distribution species is not present in the unit feed, the overall split of all other species with particle size distributions combined is used, as determined by the model. | |||
* Liquids species are split between the edge and product streams in the same proportion as solid species. | |||
* Gas phase species report directly to the product stream without split. | * Gas phase species report directly to the product stream without split. |
Latest revision as of 03:23, 19 February 2024
When the edge stream is connected, the following applies to mass splits:
- Solid species without a particle size distribution property are split to the edge stream according to the overall mass split of the default particle size distribution species selected in the SysCAD Project Configuration
- If the default particle size distribution species is not present in the unit feed, the overall split of all other species with particle size distributions combined is used, as determined by the model.
- Liquids species are split between the edge and product streams in the same proportion as solid species.
- Gas phase species report directly to the product stream without split.