Vibrating Screen (Karra): Difference between revisions
imported>Scott.Munro m (→Results) |
imported>Scott.Munro |
||
Line 84: | Line 84: | ||
The deck location factor, <math>D</math> is: | The deck location factor, <math>D</math> is: | ||
:<math>D = 1.1 | :<math>D = 1.1 - 0.1 S</math> | ||
where <math>S</math> is the location of the deck, i.e. <math>S = 1</math> is the top deck, <math>S = 2</math> is the second deck etc. | where <math>S</math> is the location of the deck, i.e. <math>S = 1</math> is the top deck, <math>S = 2</math> is the second deck etc. | ||
Line 321: | Line 321: | ||
The sections and variable names used in the SysCAD interface are described in detail in the following tables. | The sections and variable names used in the SysCAD interface are described in detail in the following tables. | ||
Note that a '''Deck''' and '''Partition''' page | Note that both a '''Deck''' page and a '''Partition''' page are provided provided for each connected oversize discharge stream. | ||
{{SysCAD (Page, Screen, DLL*Screen)}} | {{SysCAD (Page, Screen, DLL*Screen)}} |
Latest revision as of 02:24, 28 October 2023
Description
This article describes the Karra model for vibrating screen classification.[1]
Model theory
Karra provides a method of computing the classification of particles by size on a vibrating screen.[1][2]
Capacity
The capacity of a screen with particular properties is defined by the theoretical undersize transmission rate, (t/h):
where:
- is the basic capacity of the screen (t/h/m2)
- is the oversize factor
- is the half-size factor
- is the deck location factor
- is the wet screening factor
- is the bulk density factor
- is the near-size factor
- is a user defined factor
- is the length x width of the screening area.
Basic capacity (A)
The basic capacity of a screen is defined by the throughfall aperture, (mm), defined as the effective size of the aperture that a particle is presented to:
where:
- is the actual aperture of the screen (mm)
- is the width of the wire or distance between apertures (mm)
- is the angle of inclination of the screen (deg.)
The basic capacity, (t/h/m2), is then:
The basic capacity equation assumes a woven wire mesh screening surface, and is corrected for other surfaces via the factor:
The basic capacity computed above is then adjusted by the open area factor:
where (%) is the fraction of screening area consisting of apertures.
Oversize factor (B)
The oversize factor, is related to the fraction of screen fed which is larger than the throughfall aperture:
where is the fraction of screen feed which is smaller than the throughfall aperture (frac).
Half-size factor (C)
The half-size factor, is related to the fraction of screen fed which is smaller than half the throughfall aperture size, (frac):
Deck location factor (D)
The deck location factor, is:
where is the location of the deck, i.e. is the top deck, is the second deck etc.
Wet screening factor (E)
When spray water is added or slurry is screened, the wet screening factor, , is:
where
For dry screening, .
Bulk density factor (F)
The bulk density (or material weight) factor, , is:
where is the bulk density of the feed (kg/m3). See Properties (Bulk Density) for methods to estimate bulk density based on particle size distribution.
Near-size capacity factor (Gc)
The near-size capacity factor, , is:[1]
where
- is the fraction of screen feed which is smaller than 1.25 times the throughfall aperture (frac), and
- is the fraction of screen feed which is smaller than 0.75 times the throughfall aperture (frac).
Classification
The partition of particles to screen oversize is:
where:
- is the index of the size interval, , is the number of size intervals
- is the fraction of particles of size interval in the feed reporting to the oversize stream (frac)
- is the geometric mean size of the size interval (mm)
The value of (mm) is given by:
where is the mass flow rate of particles in the feed that are smaller than the throughfall aperture (t/h).
Load and efficiency
The screen load is defined as the actual rate of transmission to undersize as a fraction of the theoretical rate of transmission to undersize:
A load value less than 1.0 indicates an underloaded, oversized screen, and greater than 1.0 an overloaded, undersized screen.
A load value of 1.0 indicates the screen is sized exactly for the feed duty. Therefore, the screening area required to treat a given feed is:
The screen efficiency is defined as the fraction of sub-aperture material in the feed that is actually recovered to undersize, i.e.:
Excel
The Karra screen model may be invoked from the Excel formula bar with the following function call:
=mdUnit_Screen_Karra(Parameters as Range, Size as Range, Feed as Range)
Invoking the function with no arguments will print Help text associated with the model, including a link to this page.
Inputs
The required inputs are defined below in matrix notation with elements corresponding to cells in Excel row () x column () format:
where:
- indicates whether the wet screening factor, , should be applied (True/False)
- is the length of the screening surface in the direction of flow (m)
- is the width of the screening surface transverse to the direction of flow (m)
- is the size of the square mesh interval that feed mass is retained on (mm)
- is the number of ore types
- is feed solids mass flow rate by size and ore type (t/h)
Results
The results are displayed in Excel as an array corresponding to the matrix notation below:
where:
- is mass flow rate of solids to the oversize stream (t/h)
- is mass flow rate of solids to the undersize stream (t/h)
- is partition fraction of feed solids to the oversize stream (frac)
Example
The images below show the selection of input arrays and output results in the Excel interface.
SysCAD
The sections and variable names used in the SysCAD interface are described in detail in the following tables.
Note that both a Deck page and a Partition page are provided provided for each connected oversize discharge stream.
MD_Screen page
The first tab page in the access window will have this name.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Tag | Display | This name tag may be modified with the change tag option. |
Condition | Display | OK if no errors/warnings, otherwise lists errors/warnings. |
ConditionCount | Display | The current number of errors/warnings. If condition is OK, returns 0. |
GeneralDescription / GenDesc | Display | This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.
If this field is blank, then SysCAD will display the unit class ID. |
Requirements | ||
On | CheckBox | This enables the unit. If this box is not checked, then the MassFracToOS option appears below. |
MassFracToOS | Input | Only appears if the On field above is not checked. Specifies the fraction of feed mass that reports to the overflow stream when the model is off. |
Options | ||
ShowQFeed | CheckBox | QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream. |
SizeForPassingFracCalc | Input | Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section. |
FracForPassingSizeCalc | Input | Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section. |
Stream Summary | ||
MassFlow / Qm | Display | The total mass flow in each stream. |
SolidMassFlow / SQm | Display | The Solids mass flow in each stream. |
LiquidMassFlow / LQm | Display | The Liquid mass flow in each stream. |
VolFlow / Qv | Display | The total Volume flow in each stream. |
Temperature / T | Display | The Temperature of each stream. |
Density / Rho | Display | The Density of each stream. |
SolidFrac / Sf | Display | The Solid Fraction in each stream. |
LiquidFrac / Lf | Display | The Liquid Fraction in each stream. |
Passing | Display | The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream. |
Passes | Display | The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction. |
Deck page
The Deck page is used to specify the required model method and associated input parameters.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Deck | ||
On | Checkbox | This enables the deck. If off, the feed to this deck passes directly to the next deck (or undersize) without partition. |
Method | Partition (User) | The partition to oversize for each size interval is defined by the user. Different values can be used for different solids. |
Partition (Reid-Plitt) | The partition to oversize for each size interval is defined by a Reid-Plitt efficiency curve. Different parameters can be used for different solids. | |
Partition (Whiten-Beta) | The partition to oversize for each size interval is defined by a Whiten-Beta efficiency curve. Different parameters can be used for different solids. | |
Vibrating (Karra) | The Karra vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval. | |
Vibrating (Whiten) | The Whiten vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval. | |
Vibrating (Metso) | The Metso vibrating screen model is used to determine the partition of solids to oversize and undersize for each size interval. | |
Fine Wet (Mwale) | The Mwale fine wet screen model is used to determine the partition of solids to oversize and undersize for each size interval. | |
HelpLink | Opens a link to this page using the system default web browser. Note: Internet access is required. | |
Parameters | ||
FeedBulkDensity / RhoBulk | Input | The bulk density of the feed solids. |
DeckLocation / S | Input | Deck location, 1 = First, 2 = Second etc. |
DeckInclination / Theta | Input | Angle of inclination of the deck. |
WetScreening | Input | Indicates if the deck is wet screening (sprays, slurry etc). |
ScreenLength | Input | Length of the screen. |
ScreenWidth | Input | Width of the screen. |
Aperture / h | Input | Size of the apertures in the deck. |
WireDiameter / dw | Input | Diameter of the wire in the woven mesh screening surface (or distance between apertures). |
OpenAreaFraction / ActualOA | Input | Open area fraction of the deck. |
CustomFactor | Input | User defined factor for adjusting the theoretical screen capacity. |
Liquids | ||
LiquidsSeparMethod | Split To OS (User) | Liquids are split to oversize by a user-defined fraction of liquids in the feed. |
OS Solids Fraction | Sufficient liquids mass is recovered to the oversize stream to yield the user-defined oversize solids mass fraction value (if possible). | |
OS Liquids Fraction | Sufficient liquids mass is recovered to the oversize stream to yield the user-defined oversize liquids mass fraction value (if possible). | |
OSSolidsFracReqd / OS.SfReqd | Input | Required value of the mass fraction of solids in the oversize stream. Only visible if OS Solids Fraction is selected. |
OSLiquidsFracReqd / OS.LfReqd | Input | Required value of the mass fraction of liquids in the oversize stream. Only visible if OS Liquids Fraction is selected. |
LiqSplitToOS / OS.LiqSplit | Input/Display | The fraction of feed liquids recovered to the oversize stream. |
Results | ||
ScreenArea | Display | Area of the deck. |
ThroughfallAperture/ hT | Display | Effective aperture size experienced by particles falling under gravity. |
BasicCapacity / A | Display | Basic capacity of the screen. |
OversizeFactor / B | Display | Particle oversize screen capacity factor. |
HalfsizeFactor / C | Display | Particle halfsize screen capacity factor. |
OversizeFactor / B | Display | Oversize screen capacity factor. |
DeckLocationFactor / D | Display | Deck location screen capacity factor. |
WetScreeningFactorT / T | Display | Wet screening screen capacity factor calculation parameter. |
WetScreeningFactor / E | Display | Wet screening screen capacity factor. |
NearSizeFactor / Gc | Display | Particle near-size screen capacity factor. |
TheoreticalUndersize / Th | Display | Theoretical undersize transmission rate of the deck. |
LoadingCoefficient / K | Display | Ratio of flow rate of sub aperture material in the feed to the theoretical screen capacity. |
Halfsize | Display | Fraction of feed smaller than half the throughfall aperture. |
Nearsize | Display | Fraction of feed near the throughfall aperture size. |
Oversize | Display | Fraction of feed larger than the throughfall aperture. |
OpenAreaWire / OA | Display | Estimated open area fraction of woven wire mesh. |
RequiredArea | Display | Screening area required to treat feed stream at 100% loading. |
d50 | Display | Size at which the 50% of the feed particle mass is partitioned to oversize. |
Load | Display | Ratio of mass flow of actual undersize to theoretical transmission rate to undersize of screen. |
Efficiency | Display | Fraction of total sub-aperture sized material in feed that is actually recovered to the undersize stream. |
Partition page
The Partition page is used to specify or display the partition by species and size values.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
Distribution | ||
Name | Display | Shows the name of the SysCAD Size Distribution (PSD) quality associated with the feed stream. |
IntervalCount | Display | Shows the number of size intervals in the SysCAD Size Distribution (PSD) quality associated with the feed stream. |
SpWithPSDCount | Display | Shows the number of species in the feed stream assigned with the SysCAD Size Distribution (PSD) quality. |
Partition | ||
Method | Model/User | Select model-calculated or user-defined partition to separate each solids species type. |
Density | Display | Density of each solid species. |
Size | Display | Size of each interval in mesh series. |
MeanSize | Display | Geometric mean size of each interval in mesh series. |
All (All column) | Display |
|
Partition | Display |
|
All (All row, All column) | Display |
|
All (All row, per species) | Display |
|
About page
This page is provides product and licensing information about the Met Dynamics Models SysCAD Add-On.
Tag (Long/Short) | Input / Display | Description/Calculated Variables/Options |
---|---|---|
About | ||
HelpLink | Opens a link to the Installation and Licensing page using the system default web browser. Note: Internet access is required. | |
Information | Copies Product and License information to the Windows clipboard. | |
Product | ||
Name | Display | Met Dynamics software product name |
Version | Display | Met Dynamics software product version number. |
BuildDate | Display | Build date and time of the Met Dynamics Models SysCAD Add-On. |
License | ||
File | This is used to locate a Met Dynamics software license file. | |
Location | Display | Type of Met Dynamics software license or file name and path of license file. |
SiteCode | Display | Unique machine identifier for license authorisation. |
ReqdAuth | Display | Authorisation level required, MD-SysCAD Full or MD-SysCAD Runtime. |
Status | Display | License status, LICENSE_OK indicates a valid license, other messages report licensing errors. |
IssuedTo | Display | Only visible if Met Dynamics license file is used. Name of organisation/seat the license is authorised to. |
ExpiryDate | Display | Only visible if Met Dynamics license file is used. License expiry date. |
DaysLeft | Display | Only visible if Met Dynamics license file is used. Days left before the license expires. |
Additional notes
- Solid species that do not possess a particle size distribution property are split according to the overall mass split of the default particle size distribution species selected in the SysCAD Project Configuration.
- If the default particle size distribution species is not present in the unit feed, the overall split of all other species with particle size distributions combined is used, as determined by the model.
- Gas phase species report directly to the undersize stream without split.