Template:SysCAD (Text, Hydrocyclone, Liquids)

From Met Dynamics
Revision as of 02:59, 21 December 2022 by md>Scott.Munro
Jump to navigation Jump to search

|- ! colspan="3" style="text-align:left;" |Liquids |- style="vertical-align:top;" |rowspan="4" | LiquidsSeparMethod |Split To UF (User) |Liquids are split to underflow by a user-defined fraction of liquids in the feed. |- style="vertical-align:top;" |Split To UF (Rf) |Liquids are split to underflow by the Rf fraction computed by the hydrocyclone model (Nageswararao, Narasimha-Mainza or Plitt). |- style="vertical-align:top;" |UF Solids Fraction |Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow solids mass fraction value (if possible). |- style="vertical-align:top;" |UF Liquids Fraction |Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow liquids mass fraction value (if possible). |- |UFSolidsFracReqd |Input |Required value of the mass fraction of solids in the underflow stream. Only visible if UF Solids Fraction is selected. |- |UFLiquidsFracReqd |Input |Required value of the mass fraction of liquids in the underflow stream. Only visible if UF Liquids Fraction is selected. |- |LiqSplitToUF |style="background: #eaecf0" | Input/Display |The fraction of liquids recovered to underflow.