Line 13: Line 13:
|CheckBox
|CheckBox
|This enables the unit. If this box is not checked, then the material will pass straight through the crusher with no change to the size distribution.
|This enables the unit. If this box is not checked, then the material will pass straight through the crusher with no change to the size distribution.
{{SysCAD (Text, NumParallelUnits)|multiple=true}}
|- style="vertical-align:top;"
|- style="vertical-align:top;"
|rowspan="4" | Method
|rowspan="4" | Method

Latest revision as of 05:32, 12 November 2024

MD_HPGR page

The first tab page in the access window will have this name.

Tag (Long/Short) Input / Display Description/Calculated Variables/Options
Tag Display This name tag may be modified with the change tag option.
Condition Display OK if no errors/warnings, otherwise lists errors/warnings.
ConditionCount Display The current number of errors/warnings. If condition is OK, returns 0.
GeneralDescription / GenDesc Display This is an automatically generated description for the unit. If the user has entered text in the 'EqpDesc' field on the Info tab (see below), this will be displayed here.

If this field is blank, then SysCAD will display the unit class ID.

Requirements
On CheckBox This enables the unit. If this box is not checked, then the material will pass straight through the crusher with no change to the size distribution.
NumParallelUnits Input The number of parallel, identical units to simulate:
  • Feed is divided by the number of parallel units before being sent to the unit model.
  • Unit model products are multiplied back by the same value and returned to the SysCAD product streams.
  • All unit model result values are shown per parallel unit.
Method Fixed Discharge The discharge particle size distribution is user defined. Different distributions can be used for different solids.
Morrell-Shi-Tondo The throughput, power draw and product size distribution are determined by the Morrell-Tondo-Shi model. Different parameters can be used for different solids.
Torres The throughput, power draw and product size distribution are determined by the Torres model. Different parameters can be used for different solids.
Campos The throughput, power draw and product size distribution are determined by the Campos model. Different parameters can be used for different solids.
Options
ShowQFeed CheckBox QFeed and associated tab pages (eg Sp) will become visible, showing the properties of the combined feed stream.
ShowQProd CheckBox QProd and associated tab pages (eg Sp) will become visible, showing the properties of the products.
SizeForPassingFracCalc Input Size fraction for % Passing calculation. The size fraction input here will be shown in the Stream Summary section.
FracForPassingSizeCalc Input Fraction passing for Size calculation. The fraction input here will be shown in the Stream Summary section.
Stream Summary
MassFlow / Qm Display The total mass flow in each stream.
SolidMassFlow / SQm Display The Solids mass flow in each stream.
LiquidMassFlow / LQm Display The Liquid mass flow in each stream.
VolFlow / Qv Display The total Volume flow in each stream.
Temperature / T Display The Temperature of each stream.
Density / Rho Display The Density of each stream.
SolidFrac / Sf Display The Solid Fraction in each stream.
LiquidFrac / Lf Display The Liquid Fraction in each stream.
Passing Display The mass fraction passing the user-specified size (in the field SizeForPassingFracCalc) in each stream.
Passes Display The user-specified (in the field FracForPassesSizeCalc) fraction of material in each stream will pass this size fraction.