Template:SysCAD (Text, Hydrocyclone, Liquids): Difference between revisions
imported>Scott.Munro mNo edit summary |
imported>Scott.Munro mNo edit summary |
||
Line 13: | Line 13: | ||
{{!}}- style="vertical-align:top;" | {{!}}- style="vertical-align:top;" | ||
{{!}}Split To UF (1-C) | {{!}}Split To UF (1-C) | ||
{{!}}Liquids are split to underflow by the ''C'' (overflow) fraction specified | {{!}}Liquids are split to underflow by the ''C'' (overflow) fraction specified for the first species in the model. | ||
}} | }} | ||
|- style="vertical-align:top;" | |- style="vertical-align:top;" |
Latest revision as of 09:41, 9 June 2024
|- ! colspan="3" style="text-align:left;" |Liquids |- style="vertical-align:top;" | | LiquidsSeparMethod |Split To UF (User) |Liquids are split to underflow by a user-defined fraction of liquids in the feed.
|- style="vertical-align:top;" |UF Solids Fraction |Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow solids mass fraction value (if possible). |- style="vertical-align:top;" |UF Liquids Fraction |Sufficient liquids mass is recovered to the underflow stream to yield the user-defined underflow liquids mass fraction value (if possible). |- |UFSolidsFracReqd / UF.SfReqd |Input |Required value of the mass fraction of solids in the underflow stream. Only visible if UF Solids Fraction is selected. |- |UFLiquidsFracReqd / UF.LfReqd |Input |Required value of the mass fraction of liquids in the underflow stream. Only visible if UF Liquids Fraction is selected. |- |LiqSplitToUF / UF.LiqSplit |style="background: #eaecf0" | Input/Display |The fraction of liquids recovered to underflow.